Our product range includes a wide range of microprocessor visible spectrophotometer, double beam uv-vis spectrophotometer, single beam uv-vis spectrophotometer, uv-vis spectrophotometer, double beam uv visible spectrophotometer and spectrophotometer.
Minimum Order Quantity | 1 Piece |
Brand | Agilent |
Model | Athena |
Flow range(Min-Max) | 1000ml/min |
Operating Temperature (Celsius) | 25C |
Operating Pressure | 1 bar |
Line Size | 1/4 |
Additional Information:
Specifications:
Optical System |
Double Beam, Grating 1200 lines/mn |
Wavelength Range |
190 ~ 1100 nm |
Spectral Bandwidth |
1 nm |
Wavelength Accuracy |
0.3 nm |
Wavelength Repeatability |
0.1 nm |
Photometric Accuracy |
+ 0.3 % T ( 0 ~ 100 % T) |
Photometric Repeatability |
0.1 % T (0 ~ 100 % T) |
Photometric Range |
-4 A ~ 4A |
Stray Light |
0.05 % T |
Stability |
+ 0.001 |
Baseline Flatness |
+ 0.001 A |
Noise |
0.0005 A |
Scanning Speed |
Fast/Medium/Slow |
Wavelength Scanning |
Auto |
Keyboard |
Membrane keypad |
Light Source |
Deuterium & Tungsten lamp |
Display |
320 * 240 LCD |
Photometric Mode |
T,A,C |
Detector |
Silicon Photodiode |
Output |
USB Port & Parallel Port (Printer) |
Power |
AC 220V/50 ?Hz or AC 110V/60 Hz |
Additional Information:
Range 195 to 1000 nm with facility for automatic concentration, % Transmission, Absorbance & K Factor measurement. Automatic wavelength calibration and selection. It has sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (USB PORT). Set of 2 quartz and 4 glass cuvettes is provided.
Highly stable and accurate. Software Included (Imported) stoca kein Test/Kinetic, automatic peak picking & spectrum display. Large screen with graphic display. Spectrum and data can be printed out by printer and sent to computer via USB PORT. Set of 4 quartz and 4 glass cuvettes is provided.
Athena UV Spectrophotometer offered comprises single beam microprocessor UV/VIS spectrophotometer that is made available in range from 195 to 1000 nm as well as with facility for % Transmission, Absorbance & K Factor measurement and automatic concentration. Also coming with 4 position selector control for 10 mm path length cuvettes and sample holder support, it can easily be interfaced with any printer (RST 232C). Further, we offer the system with support of imported software as well as set of 2 quartz and 4 glass cuvettes that allows the system to perform smoothly.
Features:
· Precision designed and accurate functioning based UV Spectrophotometers
· Providing working as single beam microprocessor UV/VIS spectrophotometers
· Available in range from 195 to 1000 nm
· Coming with facility for % Transmission, Absorbance & K Factor measurement
· Also featuring support of automatic concentration
· Coming with 4 position selector control for 10 mm path length cuvettes and sample holder support
· Allows easy interfacing with any printer (RST 232C)
· System offered system with support of imported software & set of 2 quartz and 4 glass cuvettes
Technical Specifications:-
Single Beam Microprocessor UV/VIS Spectrophotometer |
Range 195 to 1000 nm with facility for automatic concentration, % Transmission, Absorbance & K Factor measurement. It has sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (RST 232C). Set of 2 quartz and 4 glass cuvettes is provided. SOFTWARE INCLUDED (Imported) |
Additional Information:
Range 195 to 1000 nm with facility for automatic concentration, % Transmission, Absorbance & K Factor measurement. Automatic wavelength calibration and selection. It has sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (USB PORT). Set of 2 quartz and 4 glass cuvettes is provided.
Highly stable and accurate. Software Included (Imported) stoca kein Test/Kinetic, automatic peak picking & spectrum display. Large screen with graphic display. Spectrum and data can be printed out by printer and sent to computer via USB PORT. Set of 4 quartz and 4 glass cuvettes is provided.
Athena UV Spectrophotometer offered comprises single beam microprocessor UV/VIS spectrophotometer that is made available in range from 195 to 1000 nm as well as with facility for % Transmission, Absorbance & K Factor measurement and automatic concentration. Also coming with 4 position selector control for 10 mm path length cuvettes and sample holder support, it can easily be interfaced with any printer (RST 232C). Further, we offer the system with support of imported software as well as set of 2 quartz and 4 glass cuvettes that allows the system to perform smoothly.
Features:
· Precision designed and accurate functioning based UV Spectrophotometers
· Providing working as single beam microprocessor UV/VIS spectrophotometers
· Available in range from 195 to 1000 nm
· Coming with facility for % Transmission, Absorbance & K Factor measurement
· Also featuring support of automatic concentration
· Coming with 4 position selector control for 10 mm path length cuvettes and sample holder support
· Allows easy interfacing with any printer (RST 232C)
· System offered system with support of imported software & set of 2 quartz and 4 glass cuvettes
Technical Specifications:-
Single Beam Microprocessor UV/VIS Spectrophotometer |
Range 195 to 1000 nm with facility for automatic concentration, % Transmission, Absorbance & K Factor measurement. It has sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (RST 232C). Set of 2 quartz and 4 glass cuvettes is provided. SOFTWARE INCLUDED (Imported) |
Additional Information:
Double Beam UV Visible Spectrophotometer
MODEL : AT-UV-2900
Double Beam UV Visible Spectrophotometer offered comes with wavelength range of 190-1100 nm, spectral bandwidth of 1 nm, working mode of T,A,C,E and double beam based optical system. Further, the system can deliver fast, medium and slow scanning speeds and have other support options including glass cells, quartz cells, fuse, instrument cover, software CD, RS 232 cable and operation manual. Some of the other standard range of the system includes photometric range of -0.3 - 3.5 A, 0 to 220 %T, wavelength accuracy of +0.3 nm, wavelength reproducibility of < 0.10 nm as well as photometric accuracy of + 0.3% T (0-100% T) & +0.002 A (0-0.1 A) among others.
Technical Specifications:-
Wavelength Range |
190-1100 nm |
Spectral Bandwidth |
1 nm |
Working Mode |
T,A,C,E |
Optical System |
Double beam |
Scanning Speed |
Fast / Medium / Slow |
Photometric Range |
-0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy |
+0.3 nm |
Wavelength Reproducibility |
< 0.10 nm |
Photometric Accuracy |
+ 0.3% T (0-100% T) |
Photometric Reproducibility |
< 0.15 % T |
Stray Light |
< 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Baseline Flatness |
+ 0.002 A |
Stability |
< 0.001A/h (at 500 nm, after warming up) |
Noise |
+0.001A (at 500 nm, after warming up) |
Detector |
Dual Silicon Photodiode |
Display |
6 inches high light blue LCD |
Power |
AC:220V + 10%, 50 Hz |
Dimensions |
630 x 470 x 210 mm |
Weight |
26 Kg |
Glass Cells |
16 No |
Quartz Cells |
4 Nos |
Fuse |
3 Nos |
Instrument Cover |
1 No |
Software CD |
1 No |
RS 232 Cable |
1 No |
Operation Manual |
1 No |
Additional Information:
Spectrophotometer/ Pharmacy Lab Equipment’s Model : AT-UV-2800
Spectrophotometer/ Pharmacy Lab Equipment’s offered comes with fast, medium and slow scanning speed options and can providing functioning support with photometric range of -0.3 - 3.5 A, 0 to 220 %T, wavelength accuracy of +0.3 nm, wavelength reproducibility of < 0.10 nm and photometric accuracy of + 0.3% T (0-100% T) & +0.002 A (0-0.1 A). Some of its other standard features include wavelength range of 190-1100 nm Czerny Turner, spectral bandwidth of 1 nm, double beam (1200 lines/mm Grating) based optical system as well as other support offered in form of software CD, RS 232 Cable, operation manual and dual silicon photodiode based detector support.
Technical Specification:-
Wavelength Range |
190-1100 nm Czerny Turner |
Spectral Bandwidth |
1 nm |
Working Mode |
Basic/Quantative/Wavelength Scan/DNA Protein Test/Kinestics (T,A,C) |
Optical System |
Double beam (1200 lines/mm Grating) |
Scanning Speed |
Fast / Medium / Slow |
Photometric Range |
-0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy |
+0.3 nm |
Wavelength Reproducibility |
< 0.10 nm |
Photometric Accuracy |
+ 0.3% T (0-100% T) |
Photometric Reproducibility |
< 0.15 % T |
Stray Light |
< 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Software CD |
1 No. |
RS 232 Cable |
1 No. |
Operation Manual |
1 No. |
Detector |
Dual Silicon Photodiode |
Display |
6 inches high light blue LCD |
Power |
AC:220V + 10%, 50 Hz. |
Dimensions |
630 x 470 x 210 mm |
Weight |
26 Kg |
Glass Cells |
16 No |
Quartz Cells |
4 Nos |
Fuse |
3 Nos |
Instrument Cover |
1 No |
Software CD |
1 No |
RS 232 Cable |
1 No |
Operation Manual |
1 No |
Additional Information:
Variable Double Beam Spectrophotometer Device offered comes with wavelength range of 190-1100 nm (1200 Lines/mm grating) as well as Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics operational modes. For efficient performance, the system can deliver Fast / Medium / Slow scanning support as well as wavelength accuracy of +0.1 nm, bandwidth of 0.5, 1,2,4,5 and wavelength reproducibility of 0.1 nm. Some of the other standard features of this system include photometric repeatability of + 0.2 % T, baseline flatness of + 0.001 A, USB based data output port and parallel printer port among others.
Technical Specification:
Wavelength Range |
190-1100 nm (1200 Lines/mm grating) |
Mode |
Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics |
Scanning Speed |
Fast / Medium / Slow |
Wavelength Accuracy |
+0.1 nm |
Bandwidth |
0.5, 1,2,4,5 |
Wavelength Reproducibility |
0.1 nm |
Photometric Display Range |
0-200 % T, -0.3 - 3.0 A, 0-9999 C |
Photometric Accuracy |
+ 0.3 % T |
Photometric Repeatability |
+ 0.2 % T |
Stability |
0.001A/h @ 500 nm |
Baseline Flatness |
+ 0.001 A |
Noise |
+0.001A |
Stray Light |
< 0.05% T @ 220nm, 360 nm) |
Data Output Port |
USB |
Printer Port |
Parallel Port |
Display |
Graphic LCD (320*240 Dots) |
Lamps |
Deuterium Lamp & Tungsten Halogen Lamp |
Detector |
Silicon Photodiode |
Dimensions(L*W*H) |
630 x 430 x 206 mm |
Net Weight |
26 Kg |
Additional Information:
We supply both standard glass cuvettes and UV cuvettes for spectrophotometers and fluorometers. As standard our Spectrophotometer cuvettes and cells have two windows polished and fluorometer cuvettes have all four walls and the base polished. All of our cuvettes also come with a range of lids and stoppers including PTFE lids and Teflon stoppers.
All of these cuvettes are available made with 3 different materials.
Optical Glass CuvettesThese cuvettes are made from Optical Glass which is suitable for transmission wavelengths from 320nm to 2,600nm and are available in a range of path lengths.
UV Quartz CuvettesUV quartz cuvettes for UV light are suitable for transmission wavelengths from 195nm to 2,500nm and are also available in a range of path lengths.
IR Quartz Cuvettes IR quartz cuvettes are suitable for wavelengths from 260nm to 3,500nm and have a matching tolerance of 1% at 2,730nmCell | Description | packaging |
10 mm Path Length | 0.7 ml Micro Cells | 2/pkg |
10 mm Path Length | 1.4 ml Semi Micro Cells | 2/pkg |
10 mm Path Length | 3.5 ml | 2/pkg |
20 mm Path Length | 2/pkg | |
40 mm Path Length | 2/pkg | |
50 mm Path Length | 2/pkg | |
100 mm Path Length | 2/pkg |
Cell | Description | packaging |
10 mm Path Length | 0.7 ml Micro Cells | 2/pkg |
10 mm Path Length | 1.4 ml Semi Micro Cells | 2/pkg |
10 mm Path Length | 3.5 ml | 2/pkg |
20 mm Path Length | 2/pkg | |
40 mm Path Length | 2/pkg | |
50 mm Path Length | 2/pkg | |
100 mm Path Length | 2/pkg |
Cell | Description | packaging |
20 mm Path Length | 5.64 ml | 2/pkg |
40 mm Path Length | N.A. | 2/pkg |
50 mm Path Length | 14.1 ml | 2/pkg |
100 mm Path Length | 28.2 ml | 2/pkg |
Additional Information:
Sr No | Path Length | Capacity | Unit |
1 | 10 mm | 3.5 ml | Pair |
2 | 1 mm | 0.35 ml | Pair |
3 | 2 mm | 0.70 ml | Pair |
4 | 5 mm | 1.7 ml | Pair |
5 | 20 mm | 7.0 ml | Pair |
6 | 30 mm | 10.5 ml | Pair |
7 | 40 mm | 14 ml | Pair |
8 | 50 mm | 17.5 ml | Pair |
9 | 100 mm | 35.0 ml | Pair |
10 | 10 mm (M) Micro | 1.0 ml | Pair |
11 | 10MM (S) (SEMI MICRO) | 1.4 ml | Pair |
12 | 10MM (U) (ULTRA MICRO) | 0.7 ml | Pair |
13 | 10MM (U) (ULTRA MICRO) | 0.5 ml | Pair |
14 | 10MM WITH STOPPER TEFLON WITH ROUND BOTTOM | 3.5 ml | Pair |
We supply both standard glass cuvettes and UV cuvettes for spectrophotometers and fluorometers. As standard our Spectrophotometer cuvettes and cells have two windows polished and fluorometer cuvettes have all four walls and the base polished. All of our cuvettes also come with a range of lids and stoppers including PTFE lids and Teflon stoppers.
All of these cuvettes are available made with 3 different materials.
Optical Glass CuvettesThese cuvettes are made from Optical Glass which is suitable for transmission wavelengths from 320nm to 2,600nm and are available in a range of path lengths.
UV Quartz CuvettesUV quartz cuvettes for UV light are suitable for transmission wavelengths from 195nm to 2,500nm and are also available in a range of path lengths.
IR Quartz Cuvettes IR quartz cuvettes are suitable for wavelengths from 260nm to 3,500nm and have a matching tolerance of 1% at 2,730nmCell | Description | packaging |
10 mm Path Length | 0.7 ml Micro Cells | 2/pkg |
10 mm Path Length | 1.4 ml Semi Micro Cells | 2/pkg |
10 mm Path Length | 3.5 ml | 2/pkg |
20 mm Path Length | 2/pkg | |
40 mm Path Length | 2/pkg | |
50 mm Path Length | 2/pkg | |
100 mm Path Length | 2/pkg |
Additional Information:
Cuvette Quartz Cuvette / Glass Cuvette
We are supplying standard cuvette with lid, standard cuvette with stopper, Micro Cuvettes with black wall, Micro Cuvette with black walls and stopper, Light-resistant mobile cuvette, Cylinder type cuvette with stopper, standard fluorescence cuvettes with stopper, Micro cuvette with white walls and lid, micro cuvette with white walls and stopper, Micro-fluorescence cuvettes with lid, micro-fluorescence cuvette, biochemistry mobile cuvette, special requirement cuvettes and so on.
Cell guaranteed transmission values on empty cells and deviations in a matched set.
Material |
Code |
Transmission On Empty Cell |
Deviation in Matching |
Optical Glass |
G |
at 350nm approx.82% |
at 350nm max.0.5% |
UV Quartz Glass |
H |
at 220nm approx.80% |
at 220nm max.0.5% |
ES Quartz Glass |
Q |
at 220nm approx.80% |
at 200nm max.0.5% |
IR Quartz Glass |
I |
at 2730nm approx.88% |
at 2730nm max.0.5% |
© Athena Technology | Website Designed and Promoted by | ITology