Positive Pressure SPE
Positive Pressure Processing Of SPE Plates Has Numerous Advantages Compared To Traditional Vacuum Manifold Processing.
Better Reproducibility Highly Uniform Flow Column-to-column
More Convenient No Caps Or Plugs Required For Open Column Ports
Easier To Use Higher Pressure Differential For Viscous Samples
Reduced Carry-over Pressure-sealed Column Processing More Powerful Built-in Nitrogen Or Air Drying Of Extracts
96-well SPE Plates SPE ware Offers A Complete Line Of Spe Plates Optimally Designed For Use With The System 96 Processor.
Based On Patented Manufacturing Technology And Using Advanced Microparticulate Sorbents, Athena SPE Plates Offer Much Higher Performance Than Conventional SPE Sorbents, With Greater Relative Capacities And Reduced Elution Volumes.
pressure+ 48 sample vial rack 12 x 32 mm
Capacity (In Tons) 96 sample
Brand Athena
Application SPE Processor
pressure+ 48 collection rack 12 x 75 mm
pressure+ 48 collection rack 13 x 100 mm
pressure+ 48 collection rack 16 x 100 mm
pressure+ 48 SPE column rack 1 ml
pressure+ 48 SPE column rack 3 ml
pressure+ 48 SPE column rack 6 ml
pressure+ 48 waste bin inserts
pressure+ 48 waste bin rack with inserts
pressure+ 96 collection tray 10 ml 24 well
pressure+ 96 column holder 96
pressure+ 96 spacer (16mm) for µelution plates
Additional Information:
144 Positive Pressure Manifold
SPE Manifold positive pressure 144 position
Purchase specification
Features Advantages
Benefits
Export : USA, Europe, Africa, Canada, Germany, France, Italy, UK, NY, NJ US, Turkey, Egypt,
Additional Information:
Minimum Order Quantity | 1 Piece |
Brand/Make | Athena |
Capacity | 300 |
Model | ASE |
Design Type | Standard |
Automated Solvent Extractor
Accelerated Solvent Extractor
Athena Fat Analyzer is based on the Soxhlet Extraction Principle and Integrates such functions as soaking, extraction, leaching, heating condensation and Solvent recovery.
Features:
Automated Cartridge Extractor
Technical parameter
Model |
AFA-1 |
Temp Range |
RT +5°C~300°C |
Measuring Range |
0.1~100 % |
Temperature Accuracy |
±0.1°C |
Sample Weight |
0.5~15gm |
Capacity |
6 pcs |
Solvent Cup Volume |
80 ml |
Solvent Recovery |
≥ 80 % |
Power Consumption |
1 kW |
Power Supply |
AC 220/110V 50/60 Hzs |
External Size (WxDxH) |
650 x 320 x 715mm |
Package Size (WxDxH) |
738 x 405 x 930mm |
Gross Weight |
54 kgs |
Applications:
Additional Information:
Positive Pressure Manifold
Positive Pressure Manifolds for simple Sample Preparation96 Positive Pressure ManifoldsAthena System 96 for Positive Pressure SPE provides uniformity of flow - something that is not achievable with conventional vacuum manifolds.
The System 96 offers an efficient solution to viscous samples. Vacuum manifolds often cannot provide adequate processing power, since the maximum pressure is limited to less than atmospheric pressure (approx. 15 psi).
96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns.
The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents.
In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.
Features and Advantages
Manufacturer of Positive Pressure Manifold System
Indian Positive Pressure Manifold
Compatible Gas Brand Athena
Additional Information:
Positive Pressure Manifolds for simple Sample Preparation96 Positive Pressure Manifolds
96 SPE
Solid Phase Extraction Unit
Specifications:-
The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents.
In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.
Features and Advantages
By using stackable collection racks and extraction racks on the Athena PRESSURE 48 96 manifold, many combinations are possible to accommodate varying methodologies. Racks only fit the system in one direction, ensuring consistent processing throughout.
Additional Information:
Minimum Order Quantity | 1 Piece |
Brand/Make | Athena |
Capacity | 300 |
Max Temperature | 99C |
Model | ASE |
Design Type | Standard |
Automated Solid Phase Extractor
Athena Fat Analyzer is based on the Soxhlet Extraction Principle and Integrates such functions as soaking, extraction, leaching, heating condensation and Solvent recovery.
Features :
Automated Extraction System uses Solid Phase Extraction technology replacing the old, labor-intensive liquid-liquid extraction technique. The procedure reduces up to 90 percent of solvent consumption when compared with the conventional methods, exhibiting a significant reduction in purchase and disposal costs of chlorinated solvents such as methylene chloride.
Technical parameter
Model |
AFA-1 |
Temp Range |
RT +5°C~300°C |
Measuring Range |
0.1~100 % |
Temperature Accuracy |
±0.1°C |
Sample Weight |
0.5~15gm |
Capacity |
6 pcs |
Solvent Cup Volume |
80 ml |
Solvent Recovery |
≥ 80 % |
Power Consumption |
1 kW |
Power Supply |
AC 220/110V 50/60 Hzs |
External Size (WxDxH) |
650 x 320 x 715mm |
Package Size (WxDxH) |
738 x 405 x 930mm |
Gross Weight |
54 kgs |
Additional Information:
Minimum Order Quantity | 1 Piece |
vacuum | 0-20 inches Hg |
SPE Vacuum Manifold System
Solid phase extraction (SPE) is a chromatographic technique used to prepare samples for subsequent analysis by removing interfering substances that may be present. The general procedure includes sorbent activation, loading, washing and eluting. This is done either by retaining the substance of interest and washing off everything else or by retaining the interfering substances and eluting the product of interest.
The vacuum SPE devices are designed to concentrate or isolate analytes from complex sample matrices. It allows processing of extraction columns with high sample throughput at minimal expense. Solvents and samples are aspirated through the columns by a vacuum of 0-20 inches Hg. Eluates are collected in tubes positioned in a removable rack inside the manifold. The 12-ports and 24-ports manifold accommodate up to 12 and 24 columns, respectively.
Application :
◆ Multiple sample processing saves time and money.
◆ Female Luer inlets fit all male Luer tipped SPE tubes and cartridges.
◆ Compatible with standard Luer-tipped SPE and filtration columns.
◆ Glass chamber allows easy visual monitoring.
◆ Adjustable racks accommodate a variety of test tubes, vials and flasks.
◆ Available in 12 and 24-position for standard tubes
The 12 Position SPE Manifold System
● Glass chamber |
● Vacuum gauge |
● 12 position cover with Luer Fittings |
● 12 Retaining Clips |
● Gasket |
● 4 Supports |
● 12 Individual Flow Control Stopcocks |
● 12 Luer Plugs |
● 3 Posts |
● Valve Assemble |
● 6 Shelves |
● Waster container |
● 12 Guide needles |
|
24 Position SPE Manifold System
● Glass chamber |
● Vacuum gauge |
● 24 position cover with Luer Fittings |
● 24 Retaining Clips |
● Gasket |
● 4 Supports |
● 24 Individual Flow Control Stopcocks |
● 24 Luer Plugs |
● 3 Posts |
● Valve Assemble |
● 4 Shelves |
● 24 Guide needles |
Additional Information:
Positive Pressure Solid Phase Extraction
SPE cartridges are used in a broad variety of labs – hospitals and toxicology service labs performing medicolegal drug testing, CRO’s for bio analytical/bio equivalence studies and food contaminants testing labs. The manual process is very labour intensive and makes operators prone to RSI. Human errors lead to lower TAT, more repeat tests and therefore higher costs and overall lowered lab efficiency. Moreover, operators are exposed to hazardous solvents posing health risks.
144 positive pressure processor for solid phase extraction columns96 positive pressure processor for solid phase extraction columns48 positive pressure processor for solid phase extraction columns Uniform flow across all columns
High end positive pressure manifold
Higher pressure. Up to 80 PSI
More effective on difficult matrices such as oral fluid, viscous urines or whole blood Active drying of the SPE bed to facilitate complete dryness
Additional Information: