Positive Pressure Manifold

Positive Pressure Manifold
  • Positive Pressure-96 Processor
  • 100 Positive Pressure Manifold
  • Positive Pressure Manifolds from SPEware
  • 96 Well Positive Pressure Manifold
  • Bio 48 Positive Pressure Manifold
  • Positive Pressure Manifold for SPE
  • Positive Pressure Manifold Streamlines Sample Preparation
  • System 48 Pressure Processor II
  • Positive Pressure Manifolds
  • 96 PRESSURE PROCESSOR II
  • System 96 Processor includes 1ml x 96 Collection Tray, 2ml x 96 Collection Tray, 10ml x 24 Waste Tray, 96 Place Sealing Gasket, Gas Supply Adapter
  • Bio 48 Positive Pressure ManifoldBio 48 Positive Pressure Manifold
Positive Pressure-96 Processor

Positive Pressure SPE

  • Solid Phase Extraction SPE
  • Positive Pressure-96 Processor
  • The New Athena System 96 Processor For Positive Pressure SPE Offers State-of-the-art Operation For SPE In 96-well Plate Formats.

Positive Pressure Processing Of SPE Plates Has Numerous Advantages Compared To Traditional Vacuum Manifold Processing.
Better Reproducibility Highly Uniform Flow Column-to-column
More Convenient No Caps Or Plugs Required For Open Column Ports
Easier To Use Higher Pressure Differential For Viscous Samples
Reduced Carry-over Pressure-sealed Column Processing More Powerful Built-in Nitrogen Or Air Drying Of Extracts
96-well SPE Plates SPE ware Offers A Complete Line Of Spe Plates Optimally Designed For Use With The System 96 Processor.
Based On Patented Manufacturing Technology And Using Advanced Microparticulate Sorbents, Athena SPE Plates Offer Much Higher Performance Than Conventional SPE Sorbents, With Greater Relative Capacities And Reduced Elution Volumes.
pressure+ 48 sample vial rack 12 x 32 mm
Capacity (In Tons) 96 sample
Brand Athena
Application SPE Processor
pressure+ 48 collection rack 12 x 75 mm
pressure+ 48 collection rack 13 x 100 mm
pressure+ 48 collection rack 16 x 100 mm
pressure+ 48 SPE column rack 1 ml
pressure+ 48 SPE column rack 3 ml
pressure+ 48 SPE column rack 6 ml
pressure+ 48 waste bin inserts
pressure+ 48 waste bin rack with inserts
pressure+ 96 collection tray 10 ml 24 well
pressure+ 96 column holder 96
pressure+ 96 spacer (16mm) for µelution plates


Additional Information:


  • Item Code: SPE 144
  • Minimum Order Quantity: 1 Piece
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 20 month
  • Delivery Time:1-2 week
  • Packaging Details: Wooden Box Packing

144 Positive Pressure Manifold

144 Positive Pressure Manifold
SPE Manifold positive pressure 144 position
Purchase specification


  • No of position : 144 individually regulated
  • No of Rows : 12
  • SPE cartridge size : 1 mL,3mL
  • Standard with equipment : 1 mL
  • SPE sizes can be switched between each size by changing the adapter plate
  • Dual setting allow users to set different pressure for extraction and column drying.
  • 2 Collection Rack for specific test tubes size
  • Includes waste reservoir with stopcock assembly to allow for direct drainage of waste.
  • Single switch raises and lowers the sample racks and creates an airtight seal.
  • Using manual positive pressure manifolds with flow restriction

Features Advantages


  • Uniform flow across all columns
  • High end positive pressure manifold
  • Higher pressure. Up to 80 PSI
  • More effective on difficult matrices such as oral fluid, viscous urines or whole blood
  • Active drying of the SPE bed to facilitate complete dryness
  • Programmable pressure profiles
  • Electronic, programmable flow control

Benefits

  • Decreased variation in column processing, improved analyte recovery reproducibility Formatted
  • for Athena SPE ware micro particulate sorbents
  • Vacuum manifolds max out at 1 Atmosphere
  • Further improves ruggedness of methods and produces more reproducible methods
  • Increased flexibility in method optimization.
  • Reduced run to run variability, reduced operator variability
  • More reproducible methods with reduced risk of errors.

Export : USA, Europe, Africa, Canada, Germany, France, Italy, UK, NY, NJ US, Turkey, Egypt,


Additional Information:

  • Item Code:SPE 144 SPE96

  • Minimum Order Quantity: 1 Piece

  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)

  • Port of Dispatch: Mumbai

  • Production Capacity: 20 month

  • Delivery Time: 1-2 weeks

  • Packaging Details: Wooden Box Packing

Accelerated Solvent Extractor
Minimum Order Quantity 1 Piece
Brand/Make Athena
Capacity 300
Model ASE
Design Type Standard

 

Automated Solvent Extractor

Accelerated Solvent Extractor
Athena Fat Analyzer is based on the Soxhlet Extraction Principle and Integrates such functions as soaking, extraction, leaching, heating condensation and Solvent recovery.
Features:

  • Microcomputer Control System
  • Audio and Visual Alarm Function
  • Integral Dry Heating, wide scope and high precision of temperature control.
  • Electric circuit is isolated from the extraction space, ensuring devices security.
  • Over-temperature alarm and timer reminding functions.
  • Abundant interface contents give simultaneous Display of set temperature, actual temperature, Set Time Heating Time.
  • Unique air insulation for temperature Heating protection and constant temperature.

Automated Cartridge Extractor

Technical parameter

Model

AFA-1

Temp Range

RT +5°C~300°C

Measuring Range

0.1~100 %

Temperature Accuracy

±0.1°C

Sample Weight

0.5~15gm

Capacity

6 pcs

Solvent Cup Volume

80 ml

Solvent Recovery

≥ 80 %

Power Consumption

1 kW

   

Power Supply

AC 220/110V 50/60 Hzs

External Size (WxDxH)

650 x 320 x 715mm

Package Size (WxDxH)

738 x 405 x 930mm

Gross Weight

54 kgs

 

Applications:
  • Pharmaceutical biotech compounds
  • Clinical samples
  • Environmental samples
  • Forensic and crime samples
  • Drugs of abuse samples
  • Food and beverage analysis
  • Agrochemical samples
  • Athena Turbo Evaporator Evaporation System efficiently concentrates samples prior to analysis by LC/MS or other analytical instruments. Turbovap II
  • increases the capacity and sample throughput in laboratories, eliminates concentration bottlenecks and maintains quality and lower costs. This instrument has 8 sample positions and enables the user to evaporate to solid state or concentrate into a fixed end-point volume.

Additional Information:

  • Item Code: ASE Dionex
  • Pay Mode Terms:L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 10 month
  • Delivery Time: 1 week
  • Packaging Details: Wooden Box

Positive Pressure Manifold

Positive Pressure Manifold


  • 48 Positive Pressure Manifold SPE
  • 96 Positive Pressure Manifold SPE
  • 144 Positive Pressure Maniold

Positive Pressure Manifolds for simple Sample Preparation96 Positive Pressure ManifoldsAthena System 96 for Positive Pressure SPE provides uniformity of flow - something that is not achievable with conventional vacuum manifolds.
The System 96 offers an efficient solution to viscous samples. Vacuum manifolds often cannot provide adequate processing power, since the maximum pressure is limited to less than atmospheric pressure (approx. 15 psi).
96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns.
The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents.
In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.


Features and Advantages


  • Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction
  • Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
  • Parallel processing for increased sample throughput
  • Easy to set-up and use with just a gas source
  • Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns
  • Built-in safety features ensure ease of use and safe operation
  • Manufacturer of Positive Pressure Manifolds
  • Modular Rack System
  • By using stackable collection racks and extraction racks on the Athena PRESSURE+ 48 96 manifold, many combinations are possible to accommodate varying methodologies. Racks
  • only fit the system in one direction, ensuring consistent processing throughout.

Manufacturer of Positive Pressure Manifold System
Indian Positive Pressure Manifold

Compatible Gas Brand Athena


Additional Information:

  • Item Code:SPE 48 144 96
  • Minimum Order Quantity: 1 Piece
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 10
  • Delivery Time: 1-2 weeks
  • Packaging Details: Wooden Box Packing

Solid Phase Extraction Unit

Positive Pressure Manifolds for simple Sample Preparation96 Positive Pressure Manifolds
96 SPE
Solid Phase Extraction Unit
Specifications:-

  • Pressure (approx. 15 psi).
  • 96 well plates,
  • Column Formats :- 1 mL 3 mL and 6 mL.

The Athena System 96 allows for gas pressures up to the supplied line pressure (typically 60-75 psi.), thus supplying greater motive force for viscous sample flow. Adjusting the pressure up or down, produces a column flow response that is smooth and immediate. The optional heated manifold provides for rapid and thorough column drying, resulting in cleaner extracts and superior specificity when working with non-polar elution solvents. In contrast, the System 96 uses unique, restricted-flow gas ports. These ports create superior flow control such that even if 95 out of 96 wells are empty, dry, or wet, the remaining single well will receive normal pressure to allow facile processing.
Features and Advantages


  • Highly uniform flow from sample to sample for SPE, Protein Precipitation and Supported Liquid Extraction
  • Improved reproducibility, accuracy and extraction efficiency, even with viscous samples
  • Parallel processing for increased sample throughput
  • Easy to set-up and use with just a gas source
  • Universal designs accommodate all 96 well plates, or 1 mL, 3 mL and 6 mL SPE columns
  • Built-in safety features ensure ease of use and safe operation
Manufacturer of Positive Pressure Manifolds
Modular Rack System

By using stackable collection racks and extraction racks on the Athena PRESSURE 48 96 manifold, many combinations are possible to accommodate varying methodologies. Racks only fit the system in one direction, ensuring consistent processing throughout.


Additional Information:

  • Item Code:SPE 48
  • Minimum Order Quantity: 1 Piece
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,Other
  • Port of Dispatch: Mumbai
  • Production Capacity: 50 month
  • Delivery Time: 1 week
  • Packaging Details: Wooden Box Packing

Automated Solid Phase Extractor
Minimum Order Quantity 1 Piece
Brand/Make Athena
Capacity 300
Max Temperature 99C
Model ASE
Design Type Standard

 

Automated Solid Phase Extractor

Athena Fat Analyzer is based on the Soxhlet Extraction Principle and Integrates such functions as soaking, extraction, leaching, heating condensation and Solvent recovery. Features :

  • Microcomputer Control System
  • Audio and Visual Alarm Function
  • Integral Dry Heating, wide scope and high precision of temperature control.
  • Electric circuit is isolated from the extraction space, ensuring devices security.
  • Over-temperature alarm and timer reminding functions.
  • Abundant interface contents give simultaneous Display of set temperature, actual temperature, Set Time Heating Time.
  • Unique air insulation for temperature Heating protection and constant temperature.
Automated Solid Phase Extractor:

Automated Extraction System uses Solid Phase Extraction technology replacing the old, labor-intensive liquid-liquid extraction technique. The procedure reduces up to 90 percent of solvent consumption when compared with the conventional methods, exhibiting a significant reduction in purchase and disposal costs of chlorinated solvents such as methylene chloride.
Technical parameter

Model

AFA-1

Temp Range

RT +5°C~300°C

Measuring Range

0.1~100 %

Temperature Accuracy

±0.1°C

Sample Weight

0.5~15gm

Capacity

6 pcs

Solvent Cup Volume

80 ml

Solvent Recovery

≥ 80 %

Power Consumption

1 kW

   

Power Supply

AC 220/110V 50/60 Hzs

External Size (WxDxH)

650 x 320 x 715mm

Package Size (WxDxH)

738 x 405 x 930mm

Gross Weight

54 kgs

 

 

Additional Information:

  • Item Code: ASE
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 10
  • Delivery Time: 1-2 week
  • Packaging Details: Wooden Box

SPE Vacuum Manifold System
Minimum Order Quantity 1 Piece
vacuum 0-20 inches Hg

 

SPE Vacuum Manifold System
Vacuum SPE Manifold

Solid phase extraction (SPE) is a chromatographic technique used to prepare samples for subsequent analysis by removing interfering substances that may be present. The general procedure includes sorbent activation, loading, washing and eluting. This is done either by retaining the substance of interest and washing off everything else or by retaining the interfering substances and eluting the product of interest.
The vacuum SPE devices are designed to concentrate or isolate analytes from complex sample matrices. It allows processing of extraction columns with high sample throughput at minimal expense. Solvents and samples are aspirated through the columns by a vacuum of 0-20 inches Hg. Eluates are collected in tubes positioned in a removable rack inside the manifold. The 12-ports and 24-ports manifold accommodate up to 12 and 24 columns, respectively.
Application :
◆ Multiple sample processing saves time and money.
◆ Female Luer inlets fit all male Luer tipped SPE tubes and cartridges.
◆ Compatible with standard Luer-tipped SPE and filtration columns.
◆ Glass chamber allows easy visual monitoring.
◆ Adjustable racks accommodate a variety of test tubes, vials and flasks.
◆ Available in 12 and 24-position for standard tubes
The 12 Position SPE Manifold System

● Glass chamber

● Vacuum gauge

● 12 position cover with Luer Fittings

● 12 Retaining Clips

● Gasket

● 4 Supports

● 12 Individual Flow Control Stopcocks

● 12 Luer Plugs

● 3 Posts

● Valve Assemble

● 6 Shelves

● Waster container

● 12 Guide needles

 

 

 

 

24 Position SPE Manifold System

● Glass chamber

● Vacuum gauge

● 24 position cover with Luer Fittings

● 24 Retaining Clips

● Gasket

● 4 Supports

● 24 Individual Flow Control Stopcocks

● 24 Luer Plugs

● 3 Posts

● Valve Assemble

● 4 Shelves

● 24 Guide needles



 

Additional Information:

  • Item Code: Vacuum SPE Manifold
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 20 month
  • Delivery Time: 1 week
  • Packaging Details:Standard Packing

Positive Pressure Solid Phase Extraction

Positive Pressure Solid Phase Extraction
SPE cartridges are used in a broad variety of labs – hospitals and toxicology service labs performing medicolegal drug testing, CRO’s for bio analytical/bio equivalence studies and food contaminants testing labs. The manual process is very labour intensive and makes operators prone to RSI. Human errors lead to lower TAT, more repeat tests and therefore higher costs and overall lowered lab efficiency. Moreover, operators are exposed to hazardous solvents posing health risks. 144 positive pressure processor for solid phase extraction columns96 positive pressure processor for solid phase extraction columns48 positive pressure processor for solid phase extraction columns Uniform flow across all columns
High end positive pressure manifold
Higher pressure. Up to 80 PSI
More effective on difficult matrices such as oral fluid, viscous urines or whole blood Active drying of the SPE bed to facilitate complete dryness


  • Decreased variation in column processing, improved analyte recovery reproducibility Formatted
  • for SPE ware microparticulate sorbents
  • Vacuum manifolds max out at 1 Atmosphere
  • Further improves ruggedness of methods and produces more reproducible methods
  • Increased flexibility in method optimization
  • Manifold Available in 48, 96 place formats
  • Reduced run to run variability, reduced operator variability More reproducible methods with reduced risk of errors
  • Programmable pressure profiles
  • Electronic, programmable flow control
  • Application SPE Positive Pressure manifold

Additional Information:

  • Item Code: SPE96
  • Minimum Order Quantity: 1 Piece
  • Pay Mode Terms:L/C (Letter of Credit),T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 20 month
  • Delivery Time: 1-2 week
  • Packaging Details: Wooden Box