Our product range includes a wide range of pensky martens apparatus, flash point apparatus, pensky marten flash point apparatus, cleaveland flash and fire point apparatus, abels flash point apparatus and red wood viscometer.
Additional Information:
Additional Information:
Pensky Marten Flash Point Apparatus
Pensky–Martens closed-cup test
Standard Test Methods for Flash Point by Pensky-Martens
The Pen sky Marten’s Apparatus is used for determining the closed Flash Point of all Petroleum HAVING A Flash point above 48.9°C (120°F), except for out-back Bitumens.
The main components of the Pen sky Martens Flash Point Apparatus are follows:
· Oil Cup
· Air Bath
· Electric Heating Arrangement
· Energy Regulator Box
· Top Plate
· Cover Assembly Having
· Cover
· Shutter
· Stirring Device
· Flame Exposure Device
· Thermometer Socket
Thermometers:
IP 15C -7°c TO 100° (LOW)
IP 16C 90°c TO 370°c(HIGH)
Either of the thermometers may be employed if the indicated reading falls within 93° to 110°C. For tests in which the indicated reading falls within the limits –7 to 93°C (20 to 200°F), the IF 15C thermometer shall be used and for tests in which the indicated reading falls within the limits 110 to 370°C (230 to 700°F) the IP 16C thermometer shall be used.
A blue print figure 1 is attached to show the constructional details.
Descriptions:
The brass oil cup is meant for heating the Petroleum Products to the Flash Point. It carries a mark all round in the inside to show the required level of liquid.
The cup has a flange which rests on the brass top and the lower parts of the cup is within the Air Bath or Heating Vessel. The top plate is screwed on the Air Bath through brass spacers, so that an air gap is produced between the cup and the Air Bath by which the transmission to the cup is almost entirely by heated air. The cup flange has an indicator to fit correctly on the Top Plate. The heat is supplied from 220V A.C. Mains, by an electric heater kept below the Air Bath and the regulation of the heat is done by the Energy regulator. The function of the Air Bath and the Top Plate is to prevent external air droughts from interfering with the heating.
PENSKY-MARTENS FLASH POINT APPARATUS
It is designed as per I.P.34, ASTMD – 93 - 58 T and I.S. 1448 (part 1)
The apparatus consists of test cup, lid, with handle, rotating shutter having pilot jet, stirrer with flexible shaft, electrically heated with Energy Regulator control suitable to operate at 220 Volt, 50 Cycles A.C Mains. It is supplied with mercury thermometer.
WITH OIL TEST JET : MODEL ATFF-04 A
WITH GAS TEST JET : MODEL ATFF-04 B
Note: Motor can be fitted with flexible shaft at an extra charge.
PENSKY-MARTENS FLASH POINT APPARATUS WITH DIGITAL TEMPERATURE INDICATOR & ELECTRONIC TEMP.REGULATOR
It is designed as per I.P.34, ASTMD – 93 - 58 T and I.S. 1448 (part 1)
The apparatus consists of test cup, lid, with handle, rotating shutter having pilot jet, stirrer with flexible shaft. It is supplied with control unit having digital temperature indicator & electronic temperature regulator. Temperature range is from 0 to 600C. , readability 1C., sensor type J type , digital display 3 &1/2 digits, operated at 220 Volt, 50 Cycles A.C Mains
WITH OIL TEST JET : MODEL ATFF-05 A
WITH GAS TEST JET : MODEL ATFF-05 B
Note: Motor can be fitted with flexible shaft at an extra charge.
Additional Information:
For determination of (OPEN CUP) flash & fire points of petroleum products and other liquids except fuel oils and those materials having an open cup flash below 79° C (175° F) as per specification IP 36 and IS 1448 [(P : 69) 19691.. The apparatus consists of a machined brass oil cup with handle. This rests on a heating plate which is covered with insulated board to prevent heat loss. There is a thermometer clip and test flame arrangement with swivel joint for passing over test liquid surface in the prescribed manner. Electrically operated heater is provided with temperature regulating device. Suitable to work on 220 V AC, 50 HZ mains.
Optional Accessories:
Additional Information:
It is designed as per I.P. 33 and I.S. 1448 (Part I) 1960 suitable for determining the close cup flash point of petroleum products.
Abel Flash Point Apparatus consist of closed Oil Cup with an internal level indicator, Stirrer, Heater, Water Bath and connecting electrical leads. A mechanically driven device for the opening of the slide and applying the ignition to the air /vapour mixture just above the sample surface is provided. It is also supplied with control unit having digital temperature indicator & electronic temperature regulator. Temperature range is from 0 to 600C. , readability 1C., sensor type J type, digital display 3 &1/2 digits, operated at 220 Volt, 50 Cycles A.C MainsAbels Flash Point Apparatus
For determination of (close cup) Flash Point of petroleum products & mixtures above 19° C and below 70°C or according to IP 33 and IP 170 and also IS 1448 (Part 1)1985 (P : 20). The apparatus consists of Brass/ Gun metal machined Cup Cover fitted with shutter mechanism, test flame arrangement (oil test jet / gas test jet), stirrer & thermometer Socket. The assembly rests in double Jacketed Copper/SS water bath. A funnel, an overflow pipe and split thermometer socket are fitted on top of the heating bath. The outer jacket of Bath is fitted with a stand. An electric heater with energy control is provided at the bottom with flexible cord.
Optional Accessories:
Additional Information:
ATFF-01 |
Abel Flash Point Apparatus |
|
A. With Oil Test Jet |
|
B. With Gas Test Jet |
ATFF-02 |
Abel Flash Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator |
|
A. With Oil Test Jet |
|
B. With Gas Test Jet |
ATFF-03 |
Continuously Variable Temp. Control For Above Unit |
ATFF-04 |
Pensky Martens Flash Point Apparatus |
|
A. With Oil Test Jet |
|
B. With Gas Test Jet |
ATFF-05 |
Pensky Martens Flash Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator |
|
A. With Oil Test Jet |
|
B. With Gas Test Jet |
ATFF-06 |
Stirrer Motor With Flexible Shaft For Above Unit |
ATFF-07 |
Continuously Variable Temp. Control For Above Unit |
ATFF-08 |
Cleavland Flash Point & Fire Point Apparatus |
ATFF-09 |
Cleavland Flash Point & Fire Point Apparatus With Digital Temp. Indicator & Electronic Temp. Regulator |
ATFF-10 |
Cloud And Pour Point Apparatus (Double Wall)S.S. |
|
For Single Test |
|
For Four Test |
ATFF-11 |
Softening Point Apparatus It Is Supplied With Thermometer I.P.61° C |
ATFF-12 |
Cone Penetrometer Apparatus |
ATFF-13 |
Penetrometer As Per Is: 2720 (Part-V) |
ATFF-14 |
Drop Point Apparatus |
ATFF-15 |
Stirring Motor With Flexible Shaft For Above Unit |
Additional Information:
This is made according to specifications laid by IP 15 and IS 1448 (P: 10) 1970. The pour point is the lowest temperature at which the oil will just fail to flow. The apparatus consists of main cooling bath made of SS Sheet, stand unit with drain plug & cover with provision for fitting thermometer & for adding freezing mixture. A glass jar for holding oil is provided with metallic Jar. The instrument is supplied with insulated body. These are available in three sizes: - Single Test, Four Test, and Six Test Model with insulated outer body. The refrigeration Model also available to test the oil sample up to -30° C range.
Optional Accessories:
Additional Information:
Additional Information:
© Athena Technology | Website Designed and Promoted by | ITology