Digital Gas Flow Meter

Digital Gas Flow Meter

Leading Manufacturer of digital bubble flowmeter, digital gas flow meter and gc flow meter from Thane.

Digital Bubble Flowmeter
Product Details:
Minimum Order Quantity 1 Piece
Brand Athena
Display Digital
Model DFM
Flow range(Min-Max) 0-2000ml/min
Operating Temperature (Celsius) 50
Operating Pressure 1
Line Size 1/4

Digital Bubble Flow meter
Our competency lies in offering our clients an excellent quality range of Digital Bubble Flow meter. Our offered flow meter detects the bubble enters and exits in the calibrated tube. This flow meter is perfectly designed with the use of impeccable grade components and latest technology under the supervision of dexterous technocrats who hold vast experience in the domain. This flow meter is highly acknowledged in the market for its easy operation and optimum finish.

Features:

  • Very reliable
  • Easy to use
  • Enhanced durability

Volumetric (Bubble) Measurement:

  • If the amount of gas exiting a column or split vent is measured in units of volume, the flow rate is volumetric based. For example, measuring the volume of gas in milliliters (mL) per unit time in minutes will result in a volumetric flow rate in mL/min. The most common device for measuring a volumetric flow rate is a bubble flowmeter. These devices are used to determine flow by measuring the time required for a gas stream to move a soap bubble through a specific volume.
  • There are several important considerations when using a bubble flowmeter:
  • The flow measurement is based on volume, and can be affected by atmospheric pressure and temperature conditions.
  • If water vapor is present, it can result in an elevated flow rate measurement. The gas being measured can diffuse rapidly through the soap bubble resulting in an erroneously low flow rate measurement. This is especially a consideration for helium and hydrogen.
  • Usually, flow rates are measured at ambient temperature and pressure. If it is necessary to compare flow rates taken under different temperature and/or pressure conditions, a correction factor relative to a set standard temperature and pressure should be applied:
  • Fref = Famb (Pamb/Pref) (/TrefTamb)

Where:


  • Fref = flow corrected to reference conditions
  • Famb = flow measured at ambient conditions
  • Pamb = atmospheric pressure at ambient conditions
  • Pref = pressure at reference conditions (1 atm commonly used)
  • Tref = temperature at reference conditions in Kelvin (K) (298 K commonly used)
  • Tamb = temperature at ambient conditions in K


Additional Information:

  • Item Code: DFM
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,D/A,Other
  • Port of Dispatch: Mumbai
  • Production Capacity: 50 monthly
  • Delivery Time: 1 weeks
Digital Gas Flow Meter
  • Product Details:
    Minimum Order Quantity 1 Piece
    Application Laboratory Use
    Brand Athena
    Model DFM4

    With sincerity and hard work of our experts, we have carved a niche for ourselves in this domain by offering Digital Gas Flow Meter. The offered flow meter is useful for measuring any gas flow rate especially for G.C. & analytical instruments. The provided flow meter is manufactured using superior quality components and advanced technology in tandem with defined industry standards. In order to ensure the functioning, this flow meter is stringently tested against practical parameters by our experts. 

    Features:

    • Direct Digital Readout
    • Microcontroller Based
    • Digital Display of LED/LCD

    Salient Features:

    • Direct Digital Readout
    • Microcontroller Based
    • Digital Display of LED/LCD
    • Useful for measuring any gas flow rate especially for G.C. &
    • Analytical Instruments.
    • Highly Accurate and fast readout
    • Easy to Operate
    • Free of Operational & Human errors
    • DFM-01, 02, 03 & 04 - Table Mounting (Soap Solution based)

    Technical Specifications:

    Flow Range DFM-01 : 1 ml/min. to 50 ml/min. with least count of 0.1 ml/min 
    DFM-02 : 5 ml/min. to 500 ml/min. with least count of 1 ml/min 
    DFM-03 : 200 ml/min. to 2000 ml/min. with least count of 1 ml/min 
    DFM-04 : 1 ml/min. to 500 ml/min. with least count of 0.1 ml/min (auto range) 
    DFM-05 : 1 ml/min. to 1000 ml/min. with least count of 0.1 ml/min (auto range) 
    DFM-06 : 10 ml/min. to 400 ml/min. with least count of 1 ml/min (auto range)
    Accuracy ±2% of Reading, ±1 Digit
    Power Supply 230 V AC, 50 Hz, 10W
    Resolution 0.1 ml/min. & 1 ml/min
    Optional Attachment Battery Operated Rechargeable System


    Additional Information:

    • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,D/A,Other
    • Port of Dispatch: Mumbai
    • Production Capacity: 50
    • Delivery Time: 1 week
GC Flow Meter
    • Product Details:
      Minimum Order Quantity 1 Piece
      Brand Agilent
      Model Athena
      Flow range(Min-Max) 1000ml/min
      Operating Temperature (Celsius) 25C
      Operating Pressure 1 bar
      Line Size 1/4

      Digital Gas Flow Meter
      Agilent ADM Gas Flow Meter
      GC Flow Meter
      • Recalibrate annually by replacing cartridge with a NIST-certified calibration cartridge
      • Measures gas volumetrically, eliminating the need to select a gas type
      • USB connects to web interface for updates and monitoring
      • Easy to view OLED screen
      • Valuable tool for troubleshooting detector problems
      • New composite materials construction
      ADM flowmeters are ideal for measuring gas streams with composite gas composition. These flow meters are easy to maintain, by simply replacing the cartridge once a year to keep the meter compliant. There is no more need to ship your meter back for a 3rd party recalibration, simply order and replace the cartridge yourself.


      Additional Information:

      • Item Code: DFM5
      • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/A
      • Port of Dispatch: Mumbai
      • Production Capacity: 50 months