Additional Information:
Micro controller based Digital Beckmann Thermometer with following:
Electronic Firing Unit With Digital Beckmann Thermometer & Printer :
Additional Information:
Digital bomb calorimeter
a) Athena Digital Bomb Calorimeter Model ATB-05 with following features
1. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
2. Digital Beckmann Thermometer (Readability 0.01ºC ) with work Test Certificate
3. Outer Jacket with Puff Insulation
4. Offset Stirrer Unit
5. Timer Buzzer 30 Sec. (for Read out)
6. Flexible Tubes of High Pressure (for Gas Filling)
7. LED Indication for sample firing
8. Known Calorific Value Benzoic Acid (with Laboratory Test Certificate Photo Copy)
a) Athena Digital Bomb Calorimeter with automatic
Calculation Model ATB -5A with following features
1. Micro controller based Digital Beckmann Thermometer with following features
a. Least count : 0.001ºC
b. Calibrated against NABL accredited (ERTL) calibrated instrument
c. Automatic result calculation
d. Memory to store last 10 results
2. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
3. Outer Jacket with Puff Insulation
4. Offset Stirrer Unit
5. Flexible Tubes of High Pressure (for Gas Filling)
6. LED Indication for sample firing
7. Known Calorific Value Benzoic Acid (with Laboratory Test Certificate Photo Copy)
a) Digital Bomb Calorimeter with automatic calculation & in-built Printer Model ATB–06 with following features
1. Micro controller based Digital Beckmann Thermometer with
following features
a. Least count : 0.001ºC
b. Calibrated against NABL accredited (ERTL) calibrated instrument
c. Automatic result calculation
d. Memory to store last 10 results
e. In built panel thermal printer
2. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
3. Outer Jacket with Puff Insulation
4. Offset Stirrer Unit
5. Flexible Tubes of High Pressure (for Gas Filling)
6. LED Indication for sample firing
7. Known Calorific Value Benzoic Acid (with Laboratory Test Certificate Photo Copy)
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Size | Oxygen |
Color | Black |
Design Type | Standard |
Brand | Athena |
d) Digital Bomb Calorimeter with automatic calculation, Printer, Computer Interface and Auto Gas Filling Unit Model ATB –07 with following features:
1. Micro controller based Digital Beckmann Thermometer with following features
2. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
3. Auto Gas filling Unit fills oxygen in bomb with constant rate every time and thus increases the repeatability of results.
4. Outer Jacket with Puff Insulation
5. Offset stirrer (heavy duty)
6. Flexible Tube of High Pressure (for Gas Filling)
7. Benzoic Acid of Known Calorific Value (with Laboratory Test Certificate Photo Copy)
SAFETY MEASURES IN MODEL ATB-07 : Incorporates latest instruments to control high pressure in Bomb automatically
Digital Bomb Calorimterer with Printer
Cat No : ATB – 06 with safety device and Water Jacket with puff Insulation
For Determination of Calorific Value Of Liquid And Solids
Bomb Calorimeter Outfit
Athena Technology provides a simple and inexpensive method for determination of heat of combustion of organic matter and the calorific valve & sulphur content of solid & liquid fuel. The outfit supplied is complete for analysis as per method recommended by British Standard Institute BS 1016. All part of outfit have finished and tested according to the specification laid down by institute of petroleum and British standard institute.
Testing Of Bomb
Each Bomb is tested before it leaves the factory. In accordance with the requirement of the institute of petroleum (I.P. 12/63 T. Appendix 1) and a works certificate is issued with each Bomb. This certificate gives the result of hydraulic testing under pressure of 300 atmospheres (4400 psi) maintain for a period of ten minutes without any sign of leakage. The maximum deformation must not exceed the specified limits.
Calorimetric Vessel
The vessel is made up of copper and is chromium plated or SS. It includes a Bomb support that ensures proper positioning of Bomb in the vessel.
Water Jacket
The outer container of Jacket is made up of Stainless Steel. The top is closed by the backellite cover called combined lid. A terminal block is fitted to the top of the container so that Connection can be made from the Electronic firing unit and provisions for water pouring and water outlet are also given at the top and bottom respectively.
Offset Stirrer
The stirring mechanism supplied gives sufficient turbulence for effective stirring whilst no heat is imparted to the calorimeter water. It consists of an impeller stirrer driven at a constant speed of approximately 800 rpm. The offset arrangement whereby the motor drives the impeller via a belt precludes any possiblility of heat transference between motor and calorimeter Vessel Contents.
Eletronic Firing Unit with Digital Beckmann Thermometer & Printer
The unit incorporates a digital Beckmann thermometer for the precise measurement of the rise in temp and electronic circuitry that provides the electrical means for firing the samples, This unit also has printer that prints the temp. reading after every 30 secs. (approx.) As the rise in temp reading are being recorder by the printer continuously so the operator is totally free to do any other job thus saving operators time and the human errors involved with recording the readings are also eliminated. Sockets for stirrer and terminals for fuse wire are also provided at the backside of the unit.
Crucible
Various types of crucible are available but the standard supplied with the outfit being a stainless steel crucible of 8 ml capacity which fits in the standard support ring provided with the outfit.
Design in accordance with the specifications of the institute of Petroleum and the British standard Institute
( As per IS : 1350 - 1966 )
Additional Information:
DIGITAL BOMB CALORIMETER
Cat No : ATB – 3 with safety device & certified Bomb
FOR DETERMINATION OF CALORIFIC VALUE OF LIQUID AND SOLIDS
BOMB CALORIMETER OUTFIT
Athena Technology provides a simple and inexpensive method for determination of heat of combustion of organic matter and the calorific valve & sulphur content of solid & liquid fuel. The outfit supplied is complete for analysis as per method recommended by British Standard Institute BS 1016. All part of outfit have finished and tested according to the specification laid down by institute of petroleum and British standard institute.
TESTING OF BOMB
Each Bomb is tested before it leaves the factory. In accordance with the requirement of the institute of petroleum (I.P. 12/63 T. Appendix 1) and a works certificate is issued with each Bomb. This certificate gives the result of hydraulic testing under pressure of 300 atmospheres (4400 psi) maintain for a period of ten minutes without any sign of leakage. The maximum deformation must not exceed the specified limits.
CALORIMETRIC VESSEL
The vessel is made up of copper and is chromium plated or SS. It includes a Bomb support that ensures proper positioning of Bomb in the vessel.
WATER JACKET
The outer container of Jacket is made up of Stainless Steel. The top is closed by the backellite cover called combined lid. A terminal block is fitted to the top of the container so that Connection can be made from the Electronic firing unit and provisions for water pouring and water outlet are also given at the top and bottom respectively.
OFFSET STIRRER
The stirring mechanism supplied gives sufficient turbulence for effective stirring whilst no heat is imparted to the calorimeter water. It consists of an impeller stirrer driven at a constant speed of approximatly 800 rpm. The offset arrangement whereby the motor drives the impeller via a belt precludes any possiblility of heat transference between motor and calorimeter Vessel Contents.
ELETRONIC FIRING UNIT WITH DIGITAL BECKMANN THERMOMETER
The unit incorporates a digital Beckmann thermometer for the precise measurement of the rise in temp and electronic circuitry that provides the electrical means for firing the samples, Sockets for stirrer, sensor and terminals for electric leads are also provided at the backside of the unit.
CRUCIBLE
Various types of crucible are availabe but the standard supplied with the outfit being a stainless steel crucible of 8 ml capacity which fits in the standard support ring provided with the outfit.
Additional Information:
The Following Components Model ATB – 5
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Athena |
Model | ATB-07 |
Application | Industrial, Laboratory |
Digital Bomb Calorimeter with automatic calculation, Printer, Computer Interface and Auto Gas Filling Unit Model ATB –07 with following features:
1. Micro controller based Digital Beckmann Thermometer with following features
2. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
3. Auto Gas filling Unit fills oxygen in bomb with constant rate every time and thus increases the repeatability of results.
4. Outer Jacket with Puff Insulation
5. Offset stirrer (heavy duty)
6. Flexible Tube of High Pressure (for Gas Filling)
7. Benzoic Acid of Known Calorific Value (with Laboratory Test Certificate Photo Copy)
SAFETY MEASURES IN MODEL ATB-07 : Incorporates latest instruments to control high pressure in Bomb automatically
Digital Bomb Calorimeter With Printer
Cat No : ATB – 06 with safety device and Water Jacket with puff Insullation
For Determination Of Calorific Value Of Liquid And Solids
Digital Bomb Calorimeter with automatic calculation & in-built Printer Model ATB–06 with following features
1. Micro controller based Digital Beckmann Thermometer with following features
2. Bomb Certified by R.T.C (Govt. Lab) (Hydraulic Pressure)
3. Outer Jacket with Puff Insulation
4. Offset Stirrer Unit
5. Flexible Tubes of High Pressure (for Gas Filling)
6. LED Indication for sample firing
7. Known Calorific Value Benzoic Acid (with Laboratory Test Certificate Photo Copy)
Electronic Firing Unit With Digital Beckmann Thermometer & Printer
The Unit Incorporates A Digital Beckmann Thermometer For The Precise Measurement Of The Rise In Temp And Electronic Circuitry That Provides The Electrical Means For Firing The Samples, This Unit Also Has Printer That Prints The Temp. Reading After Every 30 Secs. (approx.) As The Rise In Temp Reading Are Being Recorder By The Printer Continuously So The Operator Is Totally Free To Do Any Other Job Thus Saving Operators Time And The Human Errors Involved With Recording The Readings Are Also Eliminated. Sockets For Stirrer And Terminals For Fuse Wire Are Also Provided At The Backside Of The Unit.
Bomb Calorimeter Outfit
Athena Technology Provides A Simple And Inexpensive Method For Determination Of Heat Of Combustion Of Organic Matter And The Calorific Valve & Sulphur Content Of Solid & Liquid Fuel. The Outfit Supplied Is Complete For Analysis As Per Method Recommended By British Standard Institute Bs 1016. All Part Of Outfit Have Finished And Tested According To The Specification Laid Down By Institute Of Petroleum And British Standard Institute.
© Athena Technology | Website Designed and Promoted by | ITology